Chimney installation
ONLY (‘’A’’ TYPE) FACTORY BUILT CHIMNEY CAN BE USED for the installation of your GRIZZLY
fireplace. Use only 30
O
or 45
O
elbows. NO 90
O
ELBOWS ARE ALLOWED.
The use of BLACK PIPE CONNECTORS (SINGLE OR DOUBLE WALL PIPES) IS STRICTLY
PROHIBITED.
Many configurations are possible, the most frequent ones are illustrated in figures 12, 13, and 14.
Respect clearances indicated in table 1. These clearances have been tested and verified in the
course of certification and homologation sessions. Also respect factory built chimney required
clearances. See your dealer to know the specifications of the chimney manufacturer.
Figure 12 : Direct installation Figure 13 : Inside deviation installation
NOTE: It is essential to ensure yourself that
the room where the fireplace is located
sufficiently ventilated to provide an adequate
air supply.
If your home is well insulated, it is possible that
you will have to install an fresh air intake
directly from outside and routed to the unit.
Drolet Stoves & Fireplaces do not recommend
that you connect a factory built chimney to a
masonry chimney.
Figure 14 : Exterior deviation installation
THE BURNING OF ONE LITRE OF FUEL (OIL) REQUIRES APPROXIMATLY 30 m
3
OF AIR AND WILL PRODUCE ABOUT 0,8 kg OF WATER VAPOR AND 9 m
3
OF
CARBONE DIOXIDE AND ATMOSPHERIC NITROGEN. A SOURCE OF AIR FROM
THE OUTSIDE IS NEEDED TO REPLACE COMBUSTION AIR.