Page 12 of 23
Preliminary Test (cont’d)
Draught regulator :
• An excessive draught is as bad as a draught
to low.
• The regulator controls the draught when it is
excessive (in high winds for example).
• If the draught exceeds 0.08 in of water
column, you will have to adjust the regulator
Figure 19 : Draught Regulator
Adjusting the draught :
• To adjust the draught you have to screw or
unscrew the court weight on the regulator.
Regulator open lowers the draught regulator
closed increases the draught.
Figure 20 : Regulator adjustment
THE ONLY RIGHT WAY OF MEASURING THE DRAUGHT IS TO USE A DRAUGHT GAUGE THAT
GIVES READING IN INCHES OF WATER COLUMN. ALL OTHER METHOD (CANDLE, MATCHES,
ETC.) ARE UNRELIABLE.
INSTALLATION OF YOUR STOVE HAS TO BE IN ACCORDANCE WITH CAN/CSA B-139
INSTALLATION CODE FOR OIL-BURNING EQUIPMENT
IN CANADA AND STANDARD NFPA 31
NATIONAL FIRE PROTECTION ASSOCIATION STANDARD FOR OIL-BURNING EQUIPMENT
IN THE
U.S..
NOTE :
THE INSTALLATION SHALL BE MADE BY A QUALIFIED PERSON MEMBER OF THE CORPORATION
IN FORCE IN YOUR AREA.
Comments to this Manuals