OWNER`S MANUAL
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY: Do not store or use
gasoline or other flammable vapors and
liquids in the vicinity of this or any other
appliance.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
THE INSTALLATION MUST BE IN ACCORDANCE WITH LOCAL CODES OR, IN THE
ABSENCE OF LOCAL CODES, WITH THE CURRENT NATIONAL FUEL GAS CODE
ANSI Z223.1 (USA) OR THE CURRENT CAN/CGA B149 INSTALLATION CODES
(CANADA).
PLEASE KEEP THIS INSTRUCTIONS MANUAL
FOR FUTURE REFERENCE
S B I , 1700 LÉON-HARMEL, QUÉBEC, (QUÉBEC), CANADA, G1N 4R9
Tel : ( 418 ) 527-3060
Fax : ( 418 ) 527-4311
www.drolet.ca 010517/45047A_feb 03
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - OWNER`S MANUAL

SGS OWNER`S MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property d

Page 2 - TABLE OF CONTENTS

SGS GAS STOVES 9 Terminal Vent Location Your SGS stove vents through a vent terminal installed on the roof or on the outside of any exterior wall of

Page 3 - WARNINGS

SGS GAS STOVES 10 Installation of Drolet Wall Venting Kits Direct And Corner Vent Kit Installation AC02000: Coaxial 4" X 6 5/8" rigid vent

Page 4 - TECHNICAL SPECIFICATIONS

SGS GAS STOVES 11 Direct Vent Kit for Basement Installation AC02010: Coaxial 4" X 6 5/8" rigid vent system with black finish includes : 1-

Page 5 - SGS II Dimensions

SGS GAS STOVES 12 Vented Gas Stove Installation ("B-Vent") Instead of using a standard B-vent pipe it is possible to use a 4" flexibl

Page 6 - Available Options

SGS GAS STOVES 13 Stove conversion for a "B-Vent" installation only The following instructions are not for a direct vent installation. You

Page 7 - INSTALLATION

SGS GAS STOVES 14 5. Remove and discard the metallic plate (6) from the rear heat shield using a screw driver. Unscrew just a little bit the two sc

Page 8 - Clearances to combustibles

SGS GAS STOVES 15 Gas Piping • Route a 3/8" minimum NPT iron pipe gas line to the desired location. • Install a shutoff valve to the gas line.

Page 9 - Direct Vent Installation

SGS GAS STOVES 16 Ember Kit InstallationCAUTION: Blocking gas ports with rock wool will result in poor light-up performance, delayed ignition, affect

Page 10 - Terminal Vent Location

SGS GAS STOVES 17 OPERATING YOUR STOVE For your safety ATTENTION : • A QUALIFIED INSTALLER MUST PERFORM INSTALLATION OF THE APPLIANCE, VENTING, PIP

Page 11 - Restrictor

SGS GAS STOVES 18 Shut down Instructions To turn the burner OFF but leave the pilot open • Push in and rotate the gas control knob clockwise 3 to &q

Page 12

SGS GAS STOVES 1 TABLE OF CONTENTS GENERAL INFORMATION...

Page 13 - Vertical length (ft)

SGS GAS STOVES 19 The benefits of installing a blower A blower can be installed at the back of your DROLET stove. This option is necessary if you wi

Page 14

SGS GAS STOVES 20 Optional Thermodisc (AC05530) Follow the installation instructions included with the optional thermodisc. The fixation holes are l

Page 15

SGS GAS STOVES 21 MAINTENANCE INSTRUCTIONS WARNINGS : • TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICIN

Page 16 - Logs Installation

SGS GAS STOVES 22 Burner Removing the Burner • Open the glass door. Remove the burner contour (2) and the deflector (3). Unscrew the two screws on

Page 17 - SGS II)

SGS GAS STOVES 23 OPTIONS DESCRIPTION PART #Millivolt Wall Thermostat AC05558 Tangential blower with variable speed control AC02050 Direct Vent

Page 18 - OPERATING YOUR STOVE

SGS GAS STOVES 24 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site :

Page 19 - Shut down Instructions

SGS GAS STOVES 2 GENERAL INFORMATION The SGS GAS STOVE is a high-efficiency gas appliance with a maximum input rating of 28 500 BTU/h (8,4 kW) with

Page 20

SGS GAS STOVES 3 TECHNICAL SPECIFICATIONS SGS Dimensions TOP VIEW Dimensions Height : 27 3/4 po / 706 mm Width : 24 1/2 po / 621 mm Dept

Page 21

SGS GAS STOVES 4 SGS II Dimensions Dimensions Height : 27 3/4 po / 706 mm Width : 24 1/2 po / 621 mm Depth : 23 po / 585 mm Ceramic Glass F

Page 22 - MAINTENANCE INSTRUCTIONS

SGS GAS STOVES 5 Burner Natural Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : 19 000 (5,6) 28 500 (8,4) 20 000 (5,9) 26

Page 23 - Burner Installation

SGS GAS STOVES 6 INSTALLATION Before starting any installation, make sure you know : • Where you run your gas line ; • What type of venting kit yo

Page 24 - REMPLACEMENT PARTS

SGS GAS STOVES 7 Clearances to combustibles Clearance between the stove and any combustible material must also be maintained while installing your ap

Page 25 - LIMITED WARRANTY

SGS GAS STOVES 8 Direct Vent Installation Critical Length of Venting Pipes 0123456789101112131415161718192021222324252627282930012345678910Vertical l