Drolet ULC S627 Owner's Manual

Browse online or download Owner's Manual for Stoves Drolet ULC S627. Drolet ULC S627 Owner`s manual [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45063A
Printed in Canada 24-08-2011
OWNER`S MANUAL
DROLET
NG1800 WOODSTOVES:
AUSTRAL, BALTIC, LEGEND AND MYRIAD
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOODSTOVES
Verified and/or tested following
ULC S627 and UL 1482 Standards by:
Manufactured by: STOVE BUILDER INTERNATIONAL INC.
250, de Copenhague, Saint-Augustin-de-Desmaures (Québec) G3A 2H3
Tel: (418) 878-3040 Fax: (418) 878-3001
www.drolet.ca
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - WOODSTOVES:

READ AND KEEP THIS MANUAL FOR REFERENCE 45063A Printed in Canada 24-08-2011 OWNER`S MANUAL DROLET NG1800 WOODSTOVES: AUSTRAL, BALTIC, LEGEND AN

Page 2 - TABLE OF CONTENTS

10 INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATI

Page 3 - INTRODUCTION

11 CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR To install your appliance correctly, it is extremely important to respect all clearances to any comb

Page 4 - TECHNICAL SPECIFICATIONS

12 FIGURE 1.3 Clearances to combustible materials and floor protection

Page 5

13 FLOOR PROTECTOR If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible material as shown on figure

Page 6 - TIPS ON WOOD HEATING

14 Following the installation of such a heat radiation shield, the clearances mentioned on the stove certification plate may be reduced as stated in t

Page 7 - ASSEMBLY

15 Graphic 1 A- Minimum clearance required between the appliance and an unshielded combustible ceiling. B- 20 in. (500 mm) minimum; C- 1 in. (

Page 8 - AUSTRAL, LEGEND AND MYRIAD

16 Graphic 2 A- 1 in.(25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- 0.024’’ (0.61mm) sheet metal. ___________________________

Page 9 - DOOR ADJUSTMENT

17 Graphic 5 A- 1 in. (25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- Brick. __________________________________________________

Page 10 - INSTALLATION

18 CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL

Page 11

19 CHIMNEY CONNECTOR Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the stove’s exhaust outlet. The st

Page 12

2 TABLE OF CONTENTS INTRODUCTION ...

Page 13 - FLOOR PROTECTOR

20 FIGURE 2.3 (B) Minimum Slope • The assembly should be as short and direct as possible between the stove and chimney (See figure 2.4 (A)). The

Page 14 - With Shielding

21 DRAFT Your E.P.A Drolet stove’s performance will be optimised if it is installed with a chimney (flue) system that provides an adequate draft. The

Page 15 - Graphic 1

22 TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING18" CLEARANCEWALL SUPPORTWALL RADIATION SHIELDRAIN CAP Wall installation CEIL

Page 16 - Graphic 2

23 MASONRY CHIMNEY: You can also install your stove using your existing masonry chimney. To do so, follow the guidelines below. You may want to use

Page 17 - Graphique 6

24 FACTORY BUILT THIMBLE:

Page 18 - CHIMNEY

25 BRICK THIMBLE:

Page 19 - CHIMNEY CONNECTOR

26 OUTSIDE COMBUSTION AIR Your DROLET stove is approved to be installed with an outside air intake which is necessary for a mobile home. This type o

Page 20 - FIGURE 2.4 The use of elbows

27 WOODSTOVE UTILISATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials s

Page 21

28 TESTING YOUR WOOD When the stove is thoroughly warmed, place one piece of split wood (about five inches in diameter) parallel to the door on the be

Page 22 - TYPICAL INSTALLATIONS

29 HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for

Page 23 - Clean out

3 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to

Page 24 - FACTORY BUILT THIMBLE:

30 RELOADING Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few secon

Page 25

31 USE OF THE BYPASS DAMPER Your stove is equipped with a bypass damper. This feature should be used, if needed, upon start-up of the stove to help

Page 26 - OUTSIDE COMBUSTION AIR

32 ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold

Page 27 - WOODSTOVE UTILISATION

33 MAINTENANCE Your Drolet stove is a high efficiency stove and therefore requires little maintenance. It is important to perform a visual inspection

Page 28 - IGNITION

34 PAINT Only clean your stove with a dry soft cloth that will not harm the paint finish. If the paint becomes scratched or damaged, it is possible to

Page 29 - HEATING

35 BRICK LAYOUT ITEM PART # DESCRIPTION QTY 1 29015 4 X 9 BRICK 21 2 PL36022 4 X 5 3/8 BRICK 1 3 PL36054 4 X 9 BRICK (CUT) 2 4 SE16059 ASH DUMP CA

Page 30 - RELOADING

36 DROLE LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This war

Page 31 - USE OF THE BYPASS DAMPER

4 TECHNICAL SPECIFICATIONS Combustible: Wood Recommended Surface 500 to 2 100 ft2 (46 to 195 m2) Heating Capacity* : E.P.A : Seasoned cordwood: 3

Page 32 - FAN (BLOWER) OPERATION

5 *Why is the BTU indicated on the EPA label smaller than the one advertised? You will notice a difference between the BTU output as indicated on the

Page 33 - MAINTENANCE

6 TIPS ON WOOD HEATING Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Envir

Page 34

7 ASSEMBLY BALTIC Pedestal Base Installation: 1. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two s

Page 35 - BRICK LAYOUT

8 AUSTRAL, LEGEND AND MYRIAD Ash Pan Installation:

Page 36 - DESCRIPTION

9 DOOR ADJUSTMENT In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust: • R

Comments to this Manuals

No comments