45266 MODEL ECO-35 FREESTANDING OWNER’S MANUAL • Warning: If your appliance is not properly installed a house fire may result. For your safety,
10 VERTICALLY INTO EXISTING MASONRY FIREPLACE NOTE: Follow Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qua
11 OPERATION PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter an
12 UNIT CONTROLS The blowers and automatic fuel supply are controlled from the panel on the ECO-35. The control panel functions are as follows: Not
13 COMBEXtm Your stove uses a unique patented technology called COMBEX. As opposed to most other pellet stoves, which use only an exhaust blower, y
14 c. If the temperature in the auger rises beyond a certain acceptable level, two high temperature switches located under and above auger housing wi
15 THERMOSTATWIRE TERMINAL Figure 15 Thermostat terminal OPERATING THE STOVE USING A THERMOSTAT A thermostat may help you maintain a constant house
16 OPERATING SAFETY PRECAUTIONS PLEASE READ THIS! a. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup
17 MAINTENANCE MAINWALLBAFFLE Figure 17 Baffle & exhaust access panel FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PER
18 Figure 20 Baffle removal VACCUM USE If a vacuum is used to clean your stove, we suggest using a vacuum designed for ashes. Some regular vacuums
19 BLOWERS AND PRESSURE SWITCH PROBE DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. • Blower Cleaning – Over a period of
2 INTRODUCTION Thank you for purchasing the ECO-35 pellet stove. You are now prepared to burn wood in the most efficient, convenient way possible. To
20 REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remo
21 STOVE SHUTS OFF AND DISPLAYS WARNING CODE “E” Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is empty
22 STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND SHOWS WARNING CODE “L” Possible Causes: Possible Remedies: 1. Air damper open too far for ignition.
23 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE “H” Possible Causes: Possible Remedies: 1. One of the two L-250 automatic high temperat
24 THE STOVE IS RUNNING BUT DISPLAYS WARNING CODE Possibles Causes: Possibles Remedies: Warning generated by a power failure while the stove was
25 WARNING CODES MESSAGE CORRESPONDING WARNING Pressure switch error. L-250 automatic high temperature switches, located under and above the auger.
26 ELECTRICAL DIAGRAM F-160N.O.CONTROL BOARDL-250N.C.L-250RESETN.C.FRAME GROUNDL1(LINE NO CONNECTED)L2(LINE COMMON)L1(LINE HOT)THERMOSTATTERMINALSN.O.
27 REPLACEMENT PARTS Contact an Authorized DROLET Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can r
28 APPENDIX A HORIZONTAL AND VERTICAL VENT CHART Let’s imagine an installation consisting of a h
29 APPENDIX B int.ext.NameAddressCityProvince / StateCountryHome telephoneWork telephonePurchase dateModel numberSerial numberInstallation dateInst
3 SAFETY PRECAUTIONS • Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Do not unplug
30 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This
4 TABLE OF CONTENTS INTRODUCTION...
5 REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS...20 TROUBLESHOOTING ...
6 STOVE INSTALLATION 3"SIDE WALL6"2" *BACK WALL Figure 1 Back wall installation ADJACENT WALL2"ADJACENT WALL2"3"3&quo
7 COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 3” inside diameter metall
8 45 DEGREE ELBOWFOLLOW CHIMNEY OR VENT MANUFACTURER'S INSTRUCTIONSWALLTHIMBLETERMINATION COLLARCLEAN OUTTEEWALLSTRAP90 DEGREE ELBOW Figure 7 Ve
9 VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9 & 10 for basement installation) NOTE: Follow Vent chimney manufacturer’s instructions.
Comments to this Manuals