Drolet 58991 User Manual

Browse online or download User Manual for Stoves Drolet 58991. Drolet 58991 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45061A
OWNER`S MANUAL
ELDORADO, ADIRONDACK, JURASSIEN,
CELTIC AND SAVANNAH
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOODSTOVES
Verified and tested following
ULC S627 and UL 1482 Standards by:
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : ( 418 ) 527-3060
Fax : ( 418 ) 527-4311
www.drolet.ca
Page view 0
1 2 3 4 5 6 ... 26 27

Summary of Contents

Page 1 - CELTIC AND SAVANNAH

READ AND KEEP THIS MANUAL FOR REFERENCE 45061A OWNER`S MANUAL ELDORADO, ADIRONDACK, JURASSIEN, CELTIC AND SAVANNAH US ENVIRONMENTAL PROT

Page 2 - TABLE OF CONTENTS

9INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION

Page 3 - INTRODUCTION

10FLOOR PROTECTOR Your wood stove should be placed on a non-combustible surface. The floor protector should be under the stove, eighteen inches beyon

Page 4 - TECHNICAL SPECIFICATIONS

11CLEARANCES FROM COMBUSTIBLES It is of outmost importance that the clearances to combustible materials be scrupulously respected upon installation o

Page 5 - TIPS ON WOOD HEATING

12REDUCED CLEARANCES You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat

Page 6 - ASSEMBLY

13CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL

Page 7 - LEGS AND ASH PAN

14CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we rec

Page 8 - DOOR ADJUSTMENT

15TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING18" CLEARANCEWALL SUPPORTWALL RADIATION SHIELDRAIN CAP Wall installation CEIL

Page 9

16MASONRY CHIMNEY: Clay liner Thimble Clean out door

Page 10 - INSTALLATION

17FACTORY BUILT THIMBLE:

Page 11

18BRICK THIMBLE:

Page 12 - CLEARANCES FROM COMBUSTIBLES

1 TABLE OF CONTENTS INTRODUCTION ...

Page 13 - Shielding

19OUTSIDE COMBUSTION AIR Your DROLET stove is approved to be installed with an outside air intake which is necessary for a mobile home. This type o

Page 14 - CHIMNEY

20WOODSTOVE UTILISATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials s

Page 15

21Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the gro

Page 16 - TYPICAL INSTALLATIONS

22HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for

Page 17 - Clean out

23RELOADING Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few secon

Page 18 - FACTORY BUILT THIMBLE:

24ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold

Page 19

25MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require little maintenance. It is important to perform a visual inspection o

Page 20 - OUTSIDE COMBUSTION AIR

26 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This

Page 21 - WOODSTOVE UTILISATION

2 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes t

Page 22 - IGNITION

3TECHNICAL SPECIFICATIONS Combustible: Wood Recommended Surface 500 to 1 500 ft2 (47 to 140 m2) Heating Capacity : E.P.A : 44 000 BTU/h (12.8kW) Eff

Page 23 - HEATING

4TIPS ON WOOD HEATING Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Enviro

Page 24 - RELOADING

5ASSEMBLY PEDESTAL AND PANELS Pedestal Base Installation: 1. Slide the front part of the pedestal base around the pedestal and fix the rear part wi

Page 25 - ASH DISPOSAL

6LEGS AND ASH PAN Ash Lip Installation : 1. Just clip the ash lip into position, centred just below the door. 2. Slide the ash pan in position.

Page 26 - MAINTENANCE

7DOOR ADJUSTMENT In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust: • R

Page 27

8THE BENEFITS OF INSTALLING A BLOWER A blower can be installed at the back of your DROLET stove. This option is necessary if you wish to redistribut