Drolet Classic Specifications Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
Classic With Blower Installation and Operation Manual
22
5.1.2 Door adjustment
In order for your stove to burn at its best efficiency, the door must provide a perfect seal
with the firebox. Therefore, the gasket should be inspected periodically making sure to
obtain an air tight fit. Air tightness can be improved with a simple latch mechanism
adjustment. To increase the pressure on the gasket, remove one washer (A). To reduce
pressure on the door, when putting a new door gasket for example, put two washers. To
adjust:
1. Unscrew the nut.
2. Remove the door latch and the key path pin (B).
3. Remove or add one washer (A) as needed. Keep the removed washer for future
adjustment.
4. Re-install the key path pin in the key-way and slide the latch along it.
5. Secure with the nut.
5.1.3 Replacing the Door Gasket
It is important to maintain the gasket in good condition. After a year or more of use, the
door gasket will compress and become hard, which may allow air to leak past it. You can
test the condition of the door gasket by closing and latching the door on a strip of paper.
Test all around the door. If the paper slips out easily anywhere, it is time to replace the
gasket.
Use the correct replacement gasket that you can purchase from your retailer. The diameter
and density of the gasket is important to getting a good seal.
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 48 49

Comments to this Manuals

No comments