Tundra Furnace Installation and Operation Manual
43
FLOOR PROTECTION*
CANADA USA
A
18" (457 mm)
From door opening
16" (406 mm)
From door opening
B
N/A (É-U. seulement) 8" (203 mm)
C
8" (203 mm) N/A (Canada only)
D
8" (203 mm) – Note 1 N/A (Canada only)
E
N/A (É-U. only) Note 2
*Steel with a minimum thickness of 0.015" (0.38 mm) or ceramic tiles sealed together
with grout. No protection is required if the unit is installed on a non-combustible floor
(ex: concrete).
Note 1: The floor protection at the back of the furnace is limited to the furnace’s
required clearance if such clearance is smaller than 8 inches (203 mm).
Note 2: Only required under the horizontal section of the connector. Must exceed each
side of the connector by at least 2 inches (51 mm).