Drolet Savannah Specifications Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
Savannah Installation and Operation Manual
35
7.4.2 Table of Clearance Reduction Percentages
Type of shield
Clearances may be reduced by these
percentages
Sides
and rear %
Top %
(ceiling)
Can/US
A
(%)
USA
min.
Can/US
A
(%)
USA
min.
Sheet metal, a minimum of 24
gauge (0.61 mm) in thickness ,
spaced out at least 25 mm (1 in)*
by non-combustible spacers
67 12 po 50 18 po
Ceramic tiles, or equivalent non-
combustible material, on non-
combustible board spaced out at
least 25 mm (1 in)* by non-
combustible spacers
50 18 po 33 24 po
Ceramic tiles, or equivalent non-
combustible material, on non-
combustible board, with a
minimum of 24 gauge (0.61 mm)
sheet metal backing spaced out at
least 25 mm (1 in)* by non-
combustible spacers
67 12 po 50 24 po
Brick, spaced out at least 25 mm
(1 in)* by non-combustible spacers
50 18 po N/A N/A
Brick, with a minimum of 24 gauge
(0.61 mm) sheet metal backing,
spaced out at least 25 mm (1 in)*
by non-combustible spacers
67 12 po N/A N/A
* In Canada this space can be 21 mm (7/8 in)
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 53 54

Comments to this Manuals

No comments